Ozotech Poseidon Replacement cell 33218-R
Instructions for Corona Discharge Cell Replacement
*CAUTION: UNPLUG POWER SUPPLY TO OZONE GENERATOR BEFORE PERFORMING SERVICE*
1. With the cover of your specific unit removed, remove the CD cell from the ozone generator:
a. Disconnect any electrical connections between the CD cell and the electronics board.
b. Remove and discard any shipping ties that may be securing the CD cells into the ozone generator.
c. Disconnect the air inlet and ozone outlet hoses from the CD cell barb fittings.
d. Pull the CD cell straight up from the retaining clips.
2. Replace with a new CD cell in reverse order, making sure all air and electrical connections are secure.